Residual Liquid recovery Device for LPG Cylinder
Application: The device is mainly used to recover the residual liquid in the LPG cylinder
Standard: The device strictly implements the requirements of GB 8334-1999 standard for residual liquid recovery.
Working Principle: A water ring vacuum pump is used to extract the residual liquid and residual gas into the residual liquid separator, and the residdual liquid is evaporated under a negative pressure state. After being sent to the gas-water separator for separation by the water ring vacuum pump, the separated gas is directly sent to incineration furnace burning.
Features: 1.
Reasonable design
2. Safe and reliable operation
3. Entire closed system for extraction and transportation.
4. Energy saving
Technical Data:
Power |
5.5 KW |
Pump Volume |
1.5 m3/min |
Ultimate Volume |
-0.097 MPa |
Intet Diameter |
40mm |
Resdual Liquid Separator Volume |
0.47 KW |
Design Pressure of Residual Liquid Separator |
0.6 m3 |
Gas- Water Separator volume |
0.55 m3 |
Design Pressure of Air- Water Separator |
0.6 MPa |
Number of station |
4 |
|
|